| Brand Name: | Hoan |
| Model Number: | JGX-0648D-68A |
| MOQ: | 10 Pieces |
| Payment Terms: | L/C,D/A,D/P,T/T,Western Union |
The JGX-0648D-68A delivers reliable multi-directional vibration isolation through its unique helical wire rope architecture. Unlike conventional rubber or spring mounts that isolate primarily along a single axis, the wire rope design attenuates shock and vibration energy simultaneously in compression, tension, shear, and roll—making it the preferred choice for equipment exposed to complex, unpredictable vibration inputs.
The 6.8mm stainless steel wire rope is formed into 8 continuous helical loops secured between two aluminum alloy clamping blocks. When vibration or shock energy enters the system, the individual wire strands within each loop rub against one another (Coulomb friction), converting kinetic energy into low-grade thermal energy. This hysteresis-based damping mechanism:
With zero rubber, elastomer, hydraulic fluid, or moving seals, the JGX-0648D-68A requires no scheduled maintenance, lubrication, or component replacement over its entire service life. Key longevity factors include:
| Model | JGX-0648D-68A |
| Wire Rope Diameter | 6.8 mm |
| Number of Loops | 8 |
| Compression Load Range | 2 – 45 kg per isolator |
| Tension Load Range | 1 – 30 kg per isolator |
| Shear Load Range | 0.8 – 25 kg per isolator |
| Natural Frequency | 8 – 15 Hz |
| Damping Ratio (Hysteresis) | >15% |
| Transmissibility at Resonance | ≤ 3.5 |
| Operating Temperature | -75°C to +300°C |
| Material — Wire Rope | 304 Stainless Steel, Zinc-Phosphatized |
| Material — Clamping Blocks | 6061-T6 Aluminum Alloy, Hard Anodized |
| Weight | ~0.35 kg |
| Mounting | 2 * 8.5 mm through holes (M8 bolt compatible) |
For optimal performance, select a quantity of JGX-0648D-68A isolators such that each unit carries 30-60% of its rated compression load under static equipment weight. This operating range ensures sufficient deflection for effective vibration isolation while maintaining reserve capacity for shock events. Contact our application engineers for system-level isolation design support, including natural frequency calculations and multi-degree-of-freedom mounting layouts.