logo

products details

Created with Pixso. Home Created with Pixso. Products Created with Pixso.
Rubber Shock Absorber
Created with Pixso.

JZP-3.5B-SC Rubber Shock Absorber 3.5kg Load 0.3mm Static Deflection Silicone-Free Low Outgassing Cleanroom Grade

JZP-3.5B-SC Rubber Shock Absorber 3.5kg Load 0.3mm Static Deflection Silicone-Free Low Outgassing Cleanroom Grade

Brand Name: Hoan
Model Number: JZP-3.5B-SC
MOQ: 4 Pieces
Payment Terms: T/T,L/C,D/A,D/P
Detail Information
Place of Origin:
China
Certification:
ISO 9001:2015
Deflection Spread Set Of 4:
<=0.10 Mm
Resonant Frequency:
41.5+/-5 Hz (sine Sweep 5-2000 Hz, 0.5 G, 1 Oct/min)
Silicone Content:
Not Detected (infrared Screening, No D3-D6 Siloxane)
Operating Temperature:
-45 ~ +65 C
Unit Mass:
0.2 Kg
Service Life:
8 Years Continuous Duty
Application:
Cleanroom Tools, Optical Benches, Metrology Frames
Highlight:

Silicone-Free Low Outgassing Mount

,

Tight Static Deflection Tolerance

,

Cleanroom Leveling Isolator

Product Description
JZP-3.5B-SC
Silicone-Free, Low-Outgassing Rubber Shock Absorber for Cleanroom and Optical Equipment
Rated load3.5 kg per mount
Static deflection≤0.30 mm
Resonant frequency41.5 ± 5 Hz
OutgassingTML ≤0.10% / CVCM ≤0.01%
Working range-45 ~ +65 °C
Quick answer

The JZP-3.5B-SC is a 46 mm diameter metal-rubber shock absorber that carries 3.5 kg per mount, sits at a 41.5 ± 5 Hz resonant frequency and deflects 0.30 mm or less under its rated load. This version is built from an elastomer compound that contains no silicone oil and no siloxane processing aid, and the vulcanised rubber is screened to ASTM E595 limits of TML ≤0.10% and CVCM ≤0.01%. It is specified for cleanroom tools, optical benches and metrology frames where a mount has to hold a level bed and, at the same time, keep condensable film off nearby glass and coated surfaces.

Specification, with units, tolerances and test conditions

A figure without a stated test condition is a dimensional value, not a performance value. Performance rows below carry the condition under which the figure holds.

Parameter Value Tolerance Unit Test condition
Rated vertical load (Pz) 3.5 - kg Static compression, 23 ± 2 °C, 24 h dwell before reading
Static deflection at rated load ≤0.30 ±0.05 mm Rated load on a rigid platen, 23 ± 2 °C, 24 h; dial indicator resolution 0.01 mm
Deflection spread, matched set of four ≤0.10 - mm Same-lot units loaded in sequence under identical conditions
Resonant frequency 41.5 ±5 Hz Sine sweep 5–2,000 Hz, 0.5 g, 1 oct/min, base excitation
Damping ratio ≥0.13 - - Half-power bandwidth read from the transmissibility curve
Vertical stiffness, calculated ≈238 - N/mm Derived as k = (2πf)2m from 41.5 Hz and 3.5 kg; not a measured value
Static deflection implied by 41.5 Hz ≈0.14 - mm Derived as g/ω2; the 0.30 mm figure is the acceptance ceiling, not a typical reading
Impact resistance 40 - g / 11 ms Half-sine pulse with the unit at rated load
Shock endurance 100 - G / 6 ms 12 consecutive pulses per axis, three axes, base-mounted
Operating temperature -45 ~ +65 - °C 2 h soak at each limit, performance read after return to 23 °C
Total mass loss (TML) ≤0.10 - % ASTM E595, 125 °C for 24 h at pressure below 5 × 10-5 Torr
Collected volatile condensable material (CVCM) ≤0.01 - % ASTM E595, same run as the TML reading
Silicone and siloxane content Not detected - - Infrared screening of the vulcanised compound, no D3 to D6 siloxane bands
Body outer diameter (D) 46 - mm Unloaded, 23 ± 2 °C
Overall height (H) 30 ±1 mm Unloaded, 23 ± 2 °C
Unit mass 0.2 - kg As delivered, including insert
Service life 8 - year Continuous duty at rated load, -45 ~ +65 °C, cleanroom atmosphere

JZP-3.5B-SC dimension drawing

The base plate carries an M4 threaded insert on the load side and a Φ5.5 mm clearance hole on the frame side on a 40 ± 0.2 mm by 50 mm pitch. Recommended fastener torque is 2.0 N·m on clean, dry threads. Mounting surface flatness should be within 0.1 mm across the footprint; a warped frame bends the base plate and pushes bending stress into the bonded joint.

Frequency ratings: working band and test sweep range are separate figures

The two numbers below are often confused. One is the operating rating of the part; the other is merely the window in which it was qualified.

Recommended working band — operating rating
60 Hz to 2,000 Hz
Derived from √2 × 41.5 Hz = 58.7 Hz, rounded up to 60 Hz. Above this point the mount attenuates input motion instead of amplifying it, and attenuation improves steadily with frequency. From roughly 120 Hz upward the mount removes most of the transmitted motion. Continuous running between 36 Hz and 47 Hz, which covers the 41.5 ± 5 Hz resonance, is excluded from the rating.
Test sweep range — qualification only
5 Hz to 2,000 Hz
Sine sweep at 0.5 g, 1 oct/min, single-axis base excitation. The sweep exists to locate the resonance and to plot the transmissibility curve. Everything below 60 Hz in that sweep is diagnostic data and must not be quoted as an operating capability of the mount.
Selection note. Check the dominant disturbance of the tool first. Turbo pumps, linear stages and chiller compressors mostly sit above 60 Hz and are the intended targets. A disturbance below 60 Hz cannot be isolated by this stiffness and needs a softer frame solution instead of a different bolt pattern.

Performance curves, test conditions and fixture

JZP-B-SC series vibration transmissibility curve
Figure 1 – Transmissibility against excitation frequency, JZP-B-SC series.
Test conditions: sine sweep 5–2,000 Hz, constant 0.5 g input, sweep rate 1 oct/min, single-axis vertical base excitation, 23 ± 2 °C, 50% relative humidity, unit loaded at 3.5 kg.
Fixture description: rigid steel platen not thinner than 25 mm bolted to an electro-dynamic shaker; the unit is fixed through all four M4 inserts at 2.0 N·m; a control accelerometer sits on the platen directly under the unit centreline and a response accelerometer sits on the simulated payload plate above the unit. Payload plate mass equals the rated 3.5 kg so the plotted amplification peak is representative of a correctly loaded mount.
Boundary of validity: the curve applies to one unit carrying a centred vertical load of 3.5 kg. Off-centre loading, two units stacked in series, a payload mass outside 3.0–4.0 kg, or excitation applied through the side wall each shift the curve and require a fresh qualification run.
JZP-B-SC series impact response curve
Figure 2 – Impact response, JZP-B-SC series.
Test conditions: half-sine pulses of 100 G peak, 6 ms duration, 12 consecutive events per axis, three orthogonal axes, unit pre-loaded at 3.5 kg, 23 ± 2 °C.
Fixture description: drop-test machine with a rigid aluminium fixture block; unit bolted through all four M4 inserts at 2.0 N·m; accelerometer bonded to the fixture block above the unit centreline. Insert pull-out and bond-line condition are checked after the pulse train.
Boundary of validity: describes one pulse train at peak acceleration up to 100 G. Repeated random shock above that level, shock arriving through the elastomer side wall rather than the base plate, or impact while the unit is unloaded all fall outside the qualified envelope.

Selection guide for the JZP-B-SC family

Load is the first selection variable. The adjacent models in the same family share the 46 mm envelope, the 41.5 ± 5 Hz tuning and the M4 interface, so a load change rarely forces a re-design of the frame.

Model Rated load per mount Typical four-point set When to choose it
JZP-3.0B-SC 3.0 kg 12 kg Payload slightly lighter than the 3.5 kg design point
JZP-3.5B-SC 3.5 kg 14 kg Design point for the cleanroom and optical version described here
JZP-4.0B-SC 4.0 kg 16 kg Payload slightly heavier, same footprint and height
JZP-5.0B-SC 5.0 kg 20 kg Heavier sub-assembly, still inside the 46 mm envelope

Worked check. A tool weighing 14 kg on four mounts puts 3.5 kg on each one, which is the rated point. The same tool on three mounts puts 4.67 kg on each one, above the rating, and the mounts will bottom out; in that case move to JZP-5.0B-SC or add a fourth foot. Keep the centre of gravity inside the rectangle formed by the four mounts, and keep any single mount within 3.0 to 4.0 kg.

Installation procedure

  1. Check frame flatness at each foot, 0.1 mm or better across the 40 × 50 mm footprint, and remove paint or scale from the contact area.
  2. Bolt the mount to the frame at 2.0 N·m. Tighten diagonally in two passes so the base plate is not pre-bent.
  3. Lower the equipment onto the mounts with the load as close to the mount centreline as the design allows. A load offset produces a bending moment the elastomer was not specified for.
  4. Measure the gap under each foot with a feeler gauge. Differences inside the matched-set spread need no action; larger differences are corrected with shims under the frame foot, not by over-torquing the mount.
  5. Record the four gaps as the baseline for later inspection. A drift of more than 0.10 mm against this baseline indicates creep or a damaged bond and calls for replacement.

Storage, inspection and service life

  • Store between 5 °C and 35 °C, below 70% relative humidity, out of direct sunlight and away from running motors or other ozone sources. Shelf life in storage is 5 years.
  • Inspect once a year: bond line for cracks or separation, insert threads for damage, and the four installation gaps against the baseline recorded at commissioning.
  • Replace the mount when the gap has drifted more than 0.10 mm from baseline, when a bond-line crack reaches the load-bearing section, or at the end of the 8-year design life, whichever comes first.
  • No lubrication, no adjustment and no scheduled re-torque are required during the service life.

Ordering information

Supplied individually with M4 insert and Φ5.5 mm clearance hole on a 40 ± 0.2 mm by 50 mm pitch, packed in a protective bag and individual carton. Matched sets of four with a documented deflection spread of 0.10 mm or less are available; state the leveling requirement on the order so the set is selected and measured together rather than picked from stock. Minimum order is 4 pieces. Delivered in 7 to 15 working days after payment, 20,000 pieces per month available.