| Brand Name: | Hoan |
| Model Number: | JZP-4.0B-SC |
| MOQ: | 4 Pieces |
| Payment Terms: | T/T,L/C,D/P,D/A |
The JZP-4.0B-SC is a 46 mm diameter bonded rubber-to-metal shock absorber that carries 4.0 kg per mount, resonates at 41.5 ± 5 Hz, and deflects 0.30 mm or less at its rating. It is built around a high loss factor elastomer whose measured damping ratio is 0.13 or above, which is what separates it from a plain resilient pad: motion left over from an impact dies out in roughly 110 ms instead of several hundred.
The second half of the design is the fixing interface. Both faces that contact metal — the M4 insert on the load side and the Ø5.5 mm clearance seat on the frame side — carry a bonded dry-film lubricant, and the insert is chemically bonded into the elastomer rather than pressed into it. The intent is to stop contact micro-slip at the screw joint before it turns into fretting corrosion and loose preload.
Damping is easy to claim and hard to verify, so it is stated here in the three forms a test house can actually produce. The damping ratio of 0.13 comes from the width of the transmissibility peak. The logarithmic decrement of 0.82 is its time-domain twin from a decay trace with the payload released. The settling time of 110 ms is what those two numbers mean to a machine builder waiting for motion to stop before the next move.
| Behaviour | This element, ζ 0.13 | Plain resilient compound, ζ 0.05 | Consequence on the machine |
|---|---|---|---|
| Amplitude removed per cycle | about 44% | about 27% | Fewer cycles to reach the same quiet state |
| Cycles to 5% of initial amplitude | about 4.5 | about 9.5 | Decay ends in half the oscillatory events |
| Settling time at 41.5 Hz | 110 ms | 230 ms | Shorter dead time before the next commanded move |
| Peak at resonance | 3.85x | 10x | Smaller excursion during run-up and run-down |
| Floor under high-band attenuation | higher floor | lower floor | The trade: settling speed is bought with some upper-band attenuation |
That last row is the honest cost of the grade. Where a design needs the deepest possible attenuation at several hundred hertz and can tolerate a longer ring-down, the standard compound suits it better. Where the axis must be still before the next command, the high loss factor version wins the argument.
A joint can be correctly torqued, visually sound and still be failing. Two clamped faces under vibration slide against each other by micrometres; the protective oxide is rubbed off, bare metal oxidises, the layer is rubbed off again. The end state is a ring of reddish powder around the fastener, a preload that has quietly dropped, and a mount that feels loose for no visible reason.
Three features of the JZP-4.0B-SC work against that sequence:
| What you see | What it means | What to do |
|---|---|---|
| Fine reddish or dark powder ring at the screw seat | Active fretting; the protective film has been broken | Clean the seat, confirm flatness and re-torque; check that no washer was added |
| Torque falls away at the annual check | Preload lost to wear or to elastomer creep | Re-torque once to 2.0 N·m; if it falls again within a year, replace the element |
| Shiny polished patch on the base plate | Sliding contact, not the intended clamped contact | Re-check that the fixing screw is the specified grade and fully seated |
| Gap under one foot grows by more than 0.10 mm | Creep or a damaged bond line | Replace the element; do not compensate with a thicker shim alone |
| Hairline crack reaching the load-bearing section | Bond-line separation | Replace immediately; the joint strength is no longer defined |
Load per mount, not total payload, is the number that selects the element. Dividing total mass by the count is valid as long as the centre of gravity sits inside the polygon formed by the fixing points; outside it, the nearest mount carries more than its share.
| Mounting plan | System capacity at this rating | When it is the right answer |
|---|---|---|
| Three points | 12 kg | Rigid triangular frame, light payload, levelling easy with shims |
| Four points, rectangular | 16 kg | Standard layout for cabinets, benches and machine bases |
| Four points plus two outriggers | 24 kg | Long or tall payload where rocking is the concern |
Worked check. A 14 kg bench on four elements loads each one to 3.5 kg, a little under the 4.0 kg rating and comfortably inside the 3.6 to 4.4 kg band the transmissibility curve was taken in. The same bench on three elements loads each to 4.67 kg, which is over the rating: the elastomer will bottom out on shock and the curve no longer applies. Either add a fourth foot or step up to the JZP-5.0B-SC. Keep the centre of gravity inside the mounting rectangle and keep any single element between 3.6 kg and 4.4 kg, and the published numbers hold without correction.
| Feature | Size | Tolerance | Note |
|---|---|---|---|
| Body outer diameter, D | 46 mm | - | Measured unloaded at 23 ± 2 °C |
| Overall height, H | 30 mm | ±1 | Unloaded, before load is applied |
| Elastomer section height, h | 21 mm | ±0.5 | Rubber block between the two steel faces |
| Hole pitch, lengthwise, A | 40 mm | ±0.2 | Centres of the two fixing positions |
| Hole pitch, crosswise, B | 50 mm | ±0.2 | Base plate length on the same axis |
| Load-side thread, d | M4 | 6H | Bonded insert, not a pressed bush |
| Frame-side hole, d2 | Ø5.5 mm | +0.2 / 0 | Clearance hole for the fixing screw |
| Base plate corner radius, R | 5 mm | - | Rounded to avoid a stress riser |
| Base plate width | 22 mm | ±0.2 | Seating face available for clamping |
The load side carries an M4 bonded insert; the frame side carries a Ø5.5 mm clearance hole on a 40 ± 0.2 mm by 50 mm pitch. Seat flatness should be 0.1 mm or better across that footprint. A warped seat bends the base plate and pushes bending stress into the bonded joint, which shortens life long before the elastomer itself ages. Tighten diagonally in two passes so the plate is not pre-bent.
These two numbers are routinely quoted as if they were the same thing. One states how the part may be run; the other states where it was tested.
Each element ships in a protective bag in its own carton, with the M4 insert and Ø5.5 mm clearance hole on the 40 ± 0.2 mm by 50 mm pitch as standard. Matched sets of four are packed together with the deflection record so the set stays together through transport. Minimum order is 4 pieces, delivery is 7 to 15 working days after payment, and monthly capacity is 20,000 pieces. Non-silicone, low-outgassing compound options are available on request for cleanroom and optical builds; state the requirement on the order so the compound is selected before production rather than after.